AOIP-Safety megohmmeter on pyrotechnical elements (Model:IND 44)

7
543
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

 This safety megohmmeter was developed to carry continuity and isolation measurements on pyrotechnical elements where user safety is at stake.

Two types of conditions define the user safety:

Measurement conditions:

  • Measuring current much lower than the current of non-fire
  • Connection to the test line only for the activated period of measurement
  • Discharge of residual electrical charges

Safety conditions:

  • No overshoot of maximum current even in case of instrument failure (electronics breakdown, internal short-circuit…)
  • Permanent self-checking of the instrument internal functions before connection to measurement channel

Measurement principle

The principle relies on an internal device of permanent self-calibration which guarantees, over a short and long-term period of time, the high reliability of the measurements carried out by continuously correcting the drifts of gain and offset.

Measurements start with an external input signal. The result of the measurement is internally processed to supply information whether the measured value is within tolerance limits set by the operator.

All parameter settings are entered by keyboard with a locking of the parameters by key. Our units are equipped with dry contact output and S232 connection that allows process automation and implementation of traceability. 

On request, our existing products can be adapted to your specific requirements: Adapted protocole RS232, other testing voltage, integration, processing software…

Two switching units (INT 17 and INT 17 HT for high testing voltage) are also available in option to interface the devices under test (initiators, airbags…) with IND pyrotechnical ohmmeters / megohmmeters. The contact switches are usually monitored by shared automation (0 24 V) and earth bounding control (contact or transistor). Automation inputs are protected against any change of polarity.

Megohmmeter function

Range 0 MΩ to 100 MΩ
Resolution 0.1 MΩ
Accuracy ± 1% from 0 to 50 MΩ

± 2% from 50 to 100 MΩ
Measurement type 2 wires
Measuring current 10 mA (Further current on request)
Test voltage 45 V (Further voltage on request)
Cycle time < 2 s

Further features

Parameter setup – By keyboard with locking of parameters by key

– By serial link
Line offset correction By measurement of line value with validation
Triggers – 24 V at 5 mA – Programmable on opening or closing

– Dry contacts in option
Output signals Dry contacts – NO or NC, programmable for: ohmmeter channel and megohmmeter channel measurement, end of cycle
Counters – Counter: Measurement OK

– Counter: Measurement out of tolerance

– Counter: Measurement out of range

– Counter: Measurement total

General specifications

Size 280 x 155 x 290 mm
Display Backlit LCD display, 2 lines with 20 characters each

Front panel LED showing:

– Flashing green: measurement underway

– Fixed green: measurement OK

– Fixed red: measurement out of tolerance or out of range
Supply 220 VAC – 50 Hz
Communication ports RS 232 or automation

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 086 9421303 | 02873000184 | AOIP-Safety megohmmeter on pyrotechnical elements (Model:IND 44).

Comments are closed.